Baxi Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.01.05

Maximum temperature difference value between flow and return reached

Gas boiler

What it means

The temperature differential between flow and return has exceeded the maximum permitted value, indicating insufficient circulation or sensor issues.

Likely causes

  1. Insufficient boiler/installation circulation
  2. Low installation pressure
  3. Dirty heat exchanger
  4. Faulty temperature sensors
  5. Poor temperature sensor connection

Where to start

  1. Check the boiler/installation circulation
  2. Check the installation pressure
  3. Check the cleanliness of the exchanger

The full answer, free

  • 13 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 200/400/600/800 Combi 2 & System 2 Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.