Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.00.42

Pressure sensor open/faulty

Gas boiler

What it means

Reset procedure in progress following pressure sensor open/faulty condition

Likely causes

  1. Pressure sensor open or faulty
  2. Pressure gauge/sensor failure
  3. Damaged sealing washer on capillary

Where to start

  1. Drain the primary circuit and undo the nut on the pressure gauge capillary
  2. Ease the two retaining tabs holding the pressure gauge bracket away and remove the bracket
  3. Remove the gauge assembly

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 74), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.