Baxi Baxi 600/800/Assure System 2 and 600 Combi 2 platform fault H.03.54

Temporary flame loss / shutdown due to low power supply voltage

Gas boiler

What it means

Temporary flame loss combined with shutdown caused by power supply voltage being too low

Likely causes

  1. Electrode electrical connection issue
  2. Poor electrode condition
  3. Gas inlet pressure issue
  4. Incorrect gas valve calibration
  5. Air intake/flue gas exhaust terminal issue
  6. Low power supply voltage
  7. Ionisation current below 4 µA
  8. Electrode worn
  9. Electrode distances out of range

Where to start

  1. Check the electrode electrical connections
  2. Check the condition of the electrode
  3. Check the gas inlet pressure

The full answer, free

  • 13 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 75), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Baxi 600/800/Assure System 2 and 600 Combi 2 platform. Check the model on the data plate before you order parts.