Grant Aerona R32 fault C3

Lower fan motor error (HPID13R32 & HPID17R32) / fan motor error (HPID6R32 & HPID10R32)

Heat pump

What it means

Lower/single fan motor error related to Fuse CF6, Fuse CF7, fan motor or Main PCB.

Likely causes

  1. Blown Fuse CF6
  2. Blown Fuse CF7
  3. Faulty fan motor
  4. Main PCB fault

Where to start

  1. Check the electric continuity of Fuse CF6 by tester
  2. Check the electric continuity of Fuse CF7 by tester
  3. Check the voltage of Fan motor by tester

The full answer, free

  • 1 more check in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 56), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Grant manual for the Aerona R32. Check the model on the data plate before you order parts.

Other Grant Aerona R32 fault codes