Grant Boilerhouse fault 3

Flame slow to stabilise during start up

Oil boiler

What it means

Flame takes an extended time to stabilise when the burner starts, indicating combustion or draught issues.

Likely causes

  1. Insufficient air supply
  2. Poor condition of the fan
  3. Inadequate room ventilation
  4. Incorrect nozzle size and type
  5. Fuel pressure too low
  6. Insufficient draught
  7. Dirty boiler heat exchanger
  8. Poor condition of flue
  9. Debris, leaves, hair, fluff accumulation in air inlet cover and air damper
  10. Debris accumulation on fan impeller and fan housing
  11. Contamination in oil pump filter
  12. Debris or blockage accumulation in trap over time

Where to start

  1. Check the air damper setting and the condition of the fan
  2. Check room ventilation is adequate, see Section 9.1
  3. Check the nozzle size and type