Grant Euroflame fault 4

Water temperature low

Oil boiler

What it means

Boiler works but output water temperature is lower than expected.

Likely causes

  1. Undersized nozzle
  2. Low fuel pressure
  3. Dirty boiler heat exchanger
  4. Faulty boiler thermostat
  5. Incorrect combustion settings
  6. Dirty fuel filter

Where to start

  1. Check condition of boiler heat exchanger and clean if necessary
  2. Check the boiler thermostat
  3. Check the combustion settings

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 43), right under the answer

Safety: Isolate oil and power before you touch the burner. Do a combustion test after any burner adjustment or part change. OFTEC (or equivalent) work only.

From the Grant manual for the Euroflame. Check the model on the data plate before you order parts.

Other Grant Euroflame fault codes