Hitachi Yutaki M & Yutaki S fault 85
Float switch alarm
Heat pumpWhat it means
Float switch detects high level of water at drain pane, indicating malfunction of the drain pump. Requires 'Float switch' accessory configured as input signal.
Likely causes
- Water float switch at drain pan activated (closed) due to high water level in drain pan
- Blocked or malfunctioning condensate drain
- Faulty float switch or wiring
- Blocked or malfunctioning drain pump
- Faulty float switch wiring or float switch stuck closed
- Malfunction of the drain pump
- High water level at drain pane
- Compensation factor set to 0 disables compensation
- OTC set to Fix mode disables compensation
- Pump not operating within operating range
- Blocked or restricted water circuit
- Air trapped in water pipes
- Clogged water strainer
- Trapped air in hydraulic circuit after installation or service
- Water leakage causing moisture on pump surface
Where to start
- Check water level in drain pan
- Verify float switch operation and wiring to Drain pump input
- Check drain pan for blockage preventing water from draining
The full answer, free
- 23 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 335), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Hitachi manual for the Yutaki M & Yutaki S. Check the model on the data plate before you order parts.
Other Hitachi Yutaki M & Yutaki S fault codes
- 03Lost communication with all sub YUTAKI units
- 10Indoor 2nd DHW thermistor anomaly
- 100Indoor-LCD compressor protection
- 106Excessively high discharge gas temperature
- 12Indoor water outlet thermistor abnormally (THMwo)
- 15Water circuit 2 thermistor abnormally (THMwo2)
- 16Water DHW thermistor abnormally (THMdhwt)
- 17Auxiliary sensor 2 thermistor abnormally (THMaux2)
- 18Auxiliary sensor 1 thermistor abnormally (THMaux1)
- 19Activation of the protection device for the indoor fan motor
- 2Activation of protection device (high pressure cut)
- 203Sub PC-ARFH2E stops answering to main PC-ARFH2E
- 204Indoor unit stops answering to main PC-ARFH2E
- 209Sub DHW configured on unexisting module
- 21XModule X is in alarm state (sub unit)
- 22Thermistor for outdoor ambient temperature (THM7)
- 25Auxiliary sensor 3 thermistor abnormally (THMaux3)
- 3Abnormal transmission between outdoor and indoor units
- 31Incorrect capacity setting or combined capacity between outdoor and indoor units
- 35Incorrect indoor unit number setting
- 38Abnormality of picking up circuit for protection (outdoor unit)
- 4Abnormal transmission between inverter PCB and RASC unit PCB
- 40Incorrect LCD setting
- 48Activation of overcurrent protection