Hitachi Yutaki fault EE
Compressor protection
Heat pumpWhat it means
Compressor failure alarm. This alarm code appears when the following alarms 02, 07, 08, 45, 47 occur three times within 6 hours.
Likely causes
- Repeated occurrence of alarms 02, 07, 08, 45, 47 within 6 hours
- Long periods of pump/valve inactivity leading to component sticking or seizure
Where to start
- Check Water Outlet PHEX Temperature
- Check Water Flow Level and Water Pump Speed
- Check Outdoor Ambient temperature and Outdoor Ambient 2 temperature
The full answer, free
- 27 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 85), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Hitachi manual for the Yutaki. Check the model on the data plate before you order parts.