Rinnai A-series continous flow fault 11
Ignition failure
ApplianceFree account: 25 more checks, the readings and the manual page (page 36). No card needed.See the full 11 answer
What it means
Ignition failure after repeated attempts (ignition failure is less than 2 times leads to retry, this code appears after failure sequence).
Likely causes
- Gas turned off at water heater
- Gas turned off at gas meter or cylinder
- Ignition failure is less than 2 times (retry triggered)
- Flame not detected after ignition attempts
- Flame failure (current less than 1mA)
- Repeated flame failure
Where to start
- Check current fuse on PCB is normal; if not, flashing code 14 indicates fault and water flow control device full close
- Check overheat switch is normal
- Check water flow control device full open
The full answer, free
- 25 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 36), right under the answer
Safety: Isolate whatever supplies the unit has (electric, gas, water, refrigerant) and prove dead before you open it up.
Full 11 fix, readings and manual page. Free.See the full answer
From the Rinnai manual for the A-series continous flow. Check the model on the data plate before you order parts.