Samsung Gen 6 fault 101

Indoor unit communication error

Heat pump

What it means

Communication failure detected on the indoor unit communication line.

Likely causes

  1. Faulty or disconnected communication cable of indoor unit
  2. Incorrect DC output voltage at communication terminal

Where to start

  1. Check the communication cable of indoor unit
  2. Check the DC output voltage at the communication terminal
  3. Confirm comms wiring on F1/F2 to ODU if communication faults occur.

The full answer, free

  • 4 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 52), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Samsung manual for the Gen 6. Check the model on the data plate before you order parts.

Other Samsung Gen 6 fault codes