Stuart Turner Monsoon Professional fault E10
Water shortage
Shower pumpWhat it means
Pump has detected insufficient water supply at the inlet.
Likely causes
- Pump needs priming
- Water supply failed
- Pump outlet check valve stuck closed
- Inlet pipework not air tight
- Impeller damaged
- Inlet isolation valve closed
- Blocked inlet strainer
- Empty feed tank
- Air trapped in pump
Where to start
- Check water supply
- Check for leaks on inlet pipes
- Check inlet isolation valve is open
The full answer, free
- 4 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 22), right under the answer
Safety: Isolate power and water, and prove dead before you open or test the pump.
From the Stuart Turner manual for the Monsoon Professional. Check the model on the data plate before you order parts.