Trianco High Temperature Air Source Heat Pump R290 fault F07

AC input under voltage

Heat pump

What it means

AC input under voltage protection.

Likely causes

  1. Compressor Issue
  2. Fan not running or speed is too low
  3. Refrigerant leak
  4. Loose screws
  5. Fan blade or motor issue
  6. Touching components
  7. EEV step is not suitable
  8. Refrigerant amount incorrect
  9. Parameter Issue

Where to start

  1. Measure the input voltage of R/S/T of driver board if lower than 300V, it will get this protection
  2. If it's OK, replace a new compressor driver board
  3. Check correct operation of Compressor