Viessmann 200 and 222 fault fault F1
Maximum flue gas temperature exceeded 230°F (110°C) limit
Gas boilerWhat it means
Burner in fault mode due to detailed code 135: maximum flue gas temperature exceeded 230°F (110°C) limit
Likely causes
- Low heating system fill level
- Air in system
- Circulation pump fault
- Boiler water temperature sensor fault
Where to start
- Check heating system fill level
- Bleed air from system
- Check circulation pump
The full answer, free
- 2 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 2), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Viessmann manual for the 200 and 222 fault. Check the model on the data plate before you order parts.
Other Viessmann 200 and 222 fault fault codes
- 2Gas supply no/low gas pressure detected
- 33Power supply voltage is below minimal operating level; internal fuse failure
- 8Flue gas temperature has exceeded the monitoring limit
- E3Heat transfer too low during calibration
- E8Ionization current lies outside the permissible range
- EAIonization current outside permissible range during calibration (deviation too great)
- EBRepeated flame loss during calibration
- EEAt burner start, flame signal is missing or too weak
- EFFlame is lost immediately after it has built (during the safety time)
- F2Fixed high limit switch open (activated)
- F3Flame signal already present at burner start
- F9Fan speed too low during burner start
- FAFan not at standstill
- FCGas valve faulty or faulty modulation valve control; or vent system blocked
- FEDamaged or incorrect boiler coding card or main PCB
- FFInternal fault or reset button R blocked