Viessmann Vitodens 100-W fault 387

Earth fault, ionisation current

Gas boiler

What it means

Burner in a fault state. Earth fault, ionisation current. HBMU heat management unit faulty.

Likely causes

  1. Faulty ionisation electrode or connecting cable
  2. HBMU heat management unit fault
  3. Burner locked out due to a fault condition

Where to start

  1. Check ionisation electrode and connecting cable
  2. If the fault persists, replace the HBMU heat management unit
  3. Tap up/down arrows to display the fault number

The full answer, free

  • 3 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 81), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.

Other Viessmann Vitodens 100-W fault codes