Viessmann Vitodens 100-W fault 471

No heat demand, system pressure sensor not available

Gas boiler

What it means

System pressure sensor not available due to lead break or short circuit, resulting in no heat demand.

Likely causes

  1. Lead break on system pressure sensor circuit
  2. Short circuit on system pressure sensor circuit

Where to start

  1. Check system pressure sensor (plug aND)
  2. Check lead and plug-in connection
  3. Check whether the supply voltage to the sensor is 5 V

The full answer, free

  • The readings and component tests from the manual
  • The manual page for this fault (page 85), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.