Viessmann Vitodens 100-W fault 544

Emergency function activated for heating circuit 2, flow temperature sensor lead break

Gas boiler

What it means

Emergency operating mode activated for heating circuit 2 (mixer closes, heating circuit pump operational) due to a lead break on the flow temperature sensor for heating circuit 2 with mixer, or incorrect commissioning setting.

Likely causes

  1. Lead break on flow temperature sensor, heating circuit 2 with mixer
  2. Incorrect setting during commissioning

Where to start

  1. Check flow temperature sensor, mixer 2
  2. Measure voltage at sensor input on electronics module
  3. Check setting in the commissioning assistant and correct if required

The full answer, free

  • 2 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 86), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.