Viessmann Vitodens 100-W fault 59

Power supply undervoltage

Gas boiler

What it means

Burner locked out, boiler circuit pump off. No central heating, no DHW heating, caused by power supply undervoltage.

Likely causes

  1. Faulty fan connecting cables
  2. Fan power supply failure
  3. Power supply, undervoltage

Where to start

  1. Verify control unit issues a heat demand; if not, increase set value and ensure heat transfer.
  2. Verify fan starts; if not, fault 59/457 - check fan connecting cables and fan power supply.
  3. Verify ignition occurs; if not, fault 359 - check ignition module control voltage and gas supply.

The full answer, free

  • 21 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 69), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.