Viessmann Vitodens 100-W fault 69

Ionisation current lies outside the permissible range

Gas boiler

What it means

Burner enters a fault state because the ionisation current reading is outside the permissible range, with possible causes related to insulation block contact or gas solenoid valve performance.

Likely causes

  1. Insulation block touching electrode ceramic
  2. Gas solenoid valve fault
  3. Contaminated intake screen

Where to start

  1. Check whether insulation block is touching electrode ceramic
  2. Check gas solenoid valve: in service menu under 'b.6', set burner output to lower heating output for approx. 4 min; if fault occurs, replace the HBMU heat management unit
  3. In service menu under 'b.6', switch burner output from lower to upper heating output; if fault occurs during modulation, check intake screen for contamination

The full answer, free

  • 12 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.