Vokera Vibe Max fault AF2

DHW anti-freeze protection active

Gas boiler
Free account: 17 more checks, the readings and the manual page (page 29). No card needed.See the full AF2 answer

What it means

Protective status (not a fault lockout) shown when DHW anti-freeze function activates because domestic hot water probe temperature drops below 5°C. Burner ignites at minimum output, maintained until delivery water temperature reaches 55°C.

Likely causes

  1. DHW probe temperature dropped below 5°C due to low ambient temperature or boiler being off
  2. DHW probe temperature below 5°C while boiler in OFF status with electrical and fuel supply active
  3. Damaged or worn burner insulating panel

Where to start

  1. Verify DHW probe temperature reading
  2. Confirm burner ignites at minimum output during this condition
  3. Remove the burner insulating panel (D) by inserting a blade underneath the surface

The full answer, free

  • 17 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 29), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full AF2 fix, readings and manual page. Free.See the full answer

From the Vokera manual for the Vibe Max. Check the model on the data plate before you order parts.