Vokera Vision Plus Combi fault COM

Lost communication with boiler board

Gas boiler
Free account: 20 more checks, the readings and the manual page (page 43). No card needed.See the full COM answer

What it means

Transitional fault indicating loss of communication with the boiler's main control board.

Likely causes

  1. Communication wiring fault
  2. Communication link failure with boiler board
  3. Flame lockout
  4. Other alarms requiring manual reset

Where to start

  1. Isolate the appliance from the electrical supply
  2. Disconnect any external controls from terminal plug CN5 (Fig. 43)
  3. Insert a link-wire between the two wires at the 'TA' connections

The full answer, free

  • 20 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 43), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full COM fix, readings and manual page. Free.See the full answer

From the Vokera manual for the Vision Plus Combi. Check the model on the data plate before you order parts.