What it means

Gas valve fault: a flame (ionisation) signal was still detected after the gas valve was closed.

Likely causes

  1. Faulty or contaminated ionisation probe.
  2. Condensate not discharging.
  3. Gas valve coils not energised/defective gas valve.
  4. Defective control box.

Where to start

  1. Inspect the ionisation probe.
  2. Check that the condensate is discharging.
  3. Check for 230 Vac across the blue and orange wires to the gas valve coils.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 67), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.