Worcester Bosch Greenstar i System ErP fault H09

Pump communications error

Gas boiler
Free account: the readings and the manual page (page 64). No card needed.See the full H09 answer

What it means

Communication with the pump has failed: the pump's feedback signal has been lost.

Likely causes

  1. Electrical connections to the pump loose or disconnected.
  2. Incorrect pump type fitted.
  3. Pump feedback signal lost.

Where to start

  1. Check the electrical connections to the pump are fitted correctly.
  2. Check the correct pump has been fitted.
  3. Once checked, re-power the appliance to test communications.

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 64), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.