Baxi Quinta Ace fault E.00.09

THeat ex closed

Appliance

What it means

Heat exchanger temperature sensor is either shorted or measures a temperature above range

Likely causes

  1. Bad connection
  2. Incorrectly fitted sensor
  3. Faulty sensor

Where to start

  1. Check the wiring and connectors
  2. Check that the sensor has been correctly fitted
  3. Verify sensor is mounted on a façade of the area to be heated, on the north side if possible

The full answer, free

  • 2 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 79), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Baxi manual for the Quinta Ace. Check the model on the data plate before you order parts.