Ideal Logic fault C2
BCC fault (boiler chip card)
Gas boilerWhat it means
Boiler Chip Card is not correct for this boiler or is faulty
Likely causes
- Incorrect BCC fitted for boiler range/output
- BCC not securely inserted
- BCC faulty
Where to start
- Verify correct BCC for boiler is fitted (check label on BCC)
- Check BCC is securely inserted into PCB slot
- Replace BCC with new correct BCC and reset boiler
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 53), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Ideal manual for the Logic. Check the model on the data plate before you order parts.