Ideal Logic fault F5

Return thermistor fault

Gas boiler

What it means

Return temperature sensor reading is out of range or disconnected

Likely causes

  1. Return thermistor resistance out of specification
  2. Return thermistor wiring disconnected
  3. Return thermistor wiring lacks continuity to PCB
  4. PCB fault

Where to start

  1. Remove return thermistor from CH return pipe
  2. Disconnect thermistor wires
  3. Measure resistance across thermistor terminal pins using multimeter

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 49), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.