Joule Modul Air fault 80
No temperature difference across the condenser
Heat pumpWhat it means
No temperature difference detected across the condenser. Causes temporary blocking of the heat pump; it automatically restarts after 1 hour.
Likely causes
- Circulating pump fault
- Air trapped in the system
- Air trapped in pipework not purged prior to commissioning
- Kitchen ceiling valve installed too close to kitchen extractor fan
- System debris blocking filter/strainer reducing flow rate
Where to start
- Check the circulating pump operation
- Check for air in the system
- Tap the Settings icon in the main menu
The full answer, free
- 45 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 104), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Joule manual for the Modul Air. Check the model on the data plate before you order parts.