Joule Modul Air fault 95

Water pressure is critically low (< 0.3 bar)

Heat pump

What it means

System water pressure has dropped below the critical threshold of 0.3 bar. This code automatically resets when water pressure is increased.

Likely causes

  1. Low system water pressure
  2. Water leak
  3. Water pressure lower than 1 bar indicates system requires topping up

Where to start

  1. Check system water pressure gauge
  2. Check water pressure and fan/pump PWM values on Status screen
  3. Ensure system pressure is correct and system is free from air