Samsung Heat pump fault E915
DC fan non-operating
Heat pumpWhat it means
Outdoor unit DC fan motor is not operating
Likely causes
- DC fan motor power supply failure
- DC fan motor winding failure
- Fan motor connector disconnected
- Fan motor bearing seized
- Inverter PCB fault
Where to start
- Check DC fan motor connector for loose connections
- Measure voltage at fan motor terminals
- Inspect fan motor for mechanical obstruction
The full answer, free
- 5 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 85), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Samsung manual for the Heat pump. Check the model on the data plate before you order parts.