Vaillant aroTHERM fault F.723
Building circuit: pressure too low
Heat pumpWhat it means
If the filling pressure falls below the minimum pressure, the heat pump will be switched off automatically. This fault indicates the building circuit pressure is too low for safe/effective operation.
Likely causes
- Water leak in building heating circuit
- Water loss or leak in the heating water circuit
- Leak in building circuit
- Insufficient system pressure
- Leak in the heating circuit
- Loss of system pressure
Where to start
- Check building circuit water pressure via Live Monitor
- Inspect for leaks in the heating installation
- Inform competent person to top up heating water
The full answer, free
- 11 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 10), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.
Other Vaillant aroTHERM fault codes
- F.073Sensor fault: building circ. water pressure
- F.094Fault: vortex
- F.103Fault: spare part ident
- F.1117Compressor: phase failure
- F.22Heating installation filling pressure critically low
- F.514Sensor fault: compr. inlet temp
- F.517Sensor fault: compr. outlet temp
- F.519Sensor fault: building circuit return temp
- F.520Sensor fault: building circuit flow temp
- F.526Sensor fault: EEV outlet temp
- F.582Fault: EEV
- F.585Sensor fault: capac. outlet temp
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.737Condensation temperature too high
- F.741Building circuit: return temp. too low
- F.752Fault: frequency converter
- F.755Fault: 4-port valve position not correct
- F.774Sensor fault: air inlet temp
- F.788Building circuit: pump fault