Vaillant aroTHERM fault F.737
Condensation temperature too high
Heat pumpWhat it means
Temperature in the environment circuit (cooling mode) or building circuit (heating mode) too high for compressor operation.
Likely causes
- Temperature in the environment circuit (cooling mode) or building circuit (heating mode) too high for compressor operation
- Feed-in of external heat into the building circuit
- Refrigerant circuit overfilled
- Insufficient flow rate in the building circuit
- Temperature too high for compressor operation
- Heating water leak
- Loss of system pressure
- Low or high system filling pressure
- Leak in heating circuit
- Air in system
- Filling pressure outside permitted range causes flashing indication
- Loss of heating water
Where to start
- Check the back-up heater (heats up even though it is off in the sensor/actuator test?)
- Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test)
- Check the compressor outlet sensor, compressor outlet temperature sensor (TT135) and high-pressure sensor
The full answer, free
- 13 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 36), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.
Other Vaillant aroTHERM fault codes
- F.073Sensor fault: building circ. water pressure
- F.094Fault: vortex
- F.103Fault: spare part ident
- F.1117Compressor: phase failure
- F.22Heating installation filling pressure critically low
- F.514Sensor fault: compr. inlet temp
- F.517Sensor fault: compr. outlet temp
- F.519Sensor fault: building circuit return temp
- F.520Sensor fault: building circuit flow temp
- F.526Sensor fault: EEV outlet temp
- F.582Fault: EEV
- F.585Sensor fault: capac. outlet temp
- F.723Building circuit: pressure too low
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.741Building circuit: return temp. too low
- F.752Fault: frequency converter
- F.755Fault: 4-port valve position not correct
- F.774Sensor fault: air inlet temp
- F.788Building circuit: pump fault