Vaillant aroTHERM fault F.755

Fault: 4-port valve position not correct

Heat pump

What it means

Incorrect position of the 4-port diverter valve. In heating mode, the flow temperature is lower than the return temperature in the building circuit, or the temperature sensor in the electronic expansion valve environment circuit displays an incorrect temperature.

Likely causes

  1. Incorrect position of the 4-port diverter valve
  2. The temperature sensor in the electronic expansion valve environment circuit displays an incorrect temperature
  3. Flow temperature lower than return temperature in heating mode

Where to start

  1. Use the sensor/actuator test to verify the 4-port diverter valve produces an audible switching sound when actuated
  2. Check that the coil is positioned correctly on the 4-port valve
  3. Check the wiring harness and plug connections

The full answer, free

  • 37 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 36), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Vaillant manual for the aroTHERM. Check the model on the data plate before you order parts.