Vaillant VU 446/5-5 / VU 606/5-5 fault F.32

Fan fault

Gas boiler

What it means

A fault has been detected with the fan.

Likely causes

  1. Plug on fan is loose/not plugged in
  2. Multiple plug loose/not plugged in
  3. Interruption in the wiring harness
  4. Fan blocked
  5. Electronics defective

Where to start

  1. Check the plug on the fan and the plug connection.
  2. Check the multiple plug and plug connection.
  3. Check the wiring harness.

The full answer, free

  • 2 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 61), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the VU 446/5-5 / VU 606/5-5. Check the model on the data plate before you order parts.

Other Vaillant VU 446/5-5 / VU 606/5-5 fault codes