Viessmann Vitodens 100-W fault 528
Burner in a fault state, incorrect HBMU heat management unit parameter set
Gas boilerWhat it means
Burner fault state caused by the HBMU heat management unit having an incorrect parameter set loaded.
Likely causes
- Incorrect HBMU heat management unit parameter set
- Burner locked out due to a fault condition
Where to start
- Tap up/down arrows to display the fault number
- Press up and down arrows simultaneously for approx. 4 seconds
- Observe rotating bar on display indicating reset process has started
The full answer, free
- 1 more check in order
- How to put it right, step by step
- The manual page for this fault (page 86), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Viessmann manual for the Vitodens 100-W. Check the model on the data plate before you order parts.
Other Viessmann Vitodens 100-W fault codes
- 100PlusBus voltage error
- 12Short circuit, collector temperature sensor
- 161HBMU heat management unit data memory access fault
- 162Processor low voltage
- 163Checksum error, data memory access, HBMU heat management unit
- 176Condensate backup in the heat cell
- 346Ionisation current calibration error
- 347Flue gas recirculation
- 348Gas modulation valve
- 349Air mass rate flow not detected correctly in fan unit
- 350Ionisation current lies outside the permissible range
- 351Ionisation current lies outside the permissible range
- 352Combustion CO limit exceeded
- 355Analogue signal reference check: flame signal already present at burner start
- 359No ignition spark, burner in fault state
- 361Flame signal not present or insufficient at burner start
- 364Internal fault, burner in fault state
- 368Gas pressure switch fault, burner locked out
- 369Flame lost immediately after flame formation (during safety time)
- 371Fan speed too low
- 372Repeated flame loss during calibration
- 373Heat transfer too low during calibration, temperature limiter shut down
- 374Burner restarts, stabilisation conditions for pre-calibration not met
- 375Ionisation current calibration not performed