Vokera Pinnacle Combi fault E041
Low water pressure (temporary fault)
Gas boilerWhat it means
Temporary fault indicating the boiler is not working properly due to low water pressure. Operation required within 10 minutes of message appearing, otherwise the anomaly becomes definitive (E040).
Likely causes
- System water pressure dropped significantly
- Water leak in heating system
- Failure to top up system after FIL warning
Where to start
- Check Water pressure reading for system pressure
- Check system pressure on LCD display or gauge on underside of appliance
- Check pressure transducer operation if burner/pump/fan de-activate on low pressure
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 6), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Vokera manual for the Pinnacle Combi. Check the model on the data plate before you order parts.
Other Vokera Pinnacle Combi fault codes
- COMAppliance PCB communication lost
- E010Maximum number of ignition attempts
- E011Parasitic flame
- E034Chimney obstruction in preventilation
- E035Blockage obstruction flue gas low power
- E036Blockage obstruction flue gas high power
- E042Water transducer - LWCO error
- E050Smoke obstruction error low power
- E051Smoke obstruction error high power
- E055No card fan communication
- E056No communication microprocessor card
- E070CH probe error
- E071Heating temperature over limit
- E072Delta T return out of limit
- E077Absence of communication with low temperature thermostat
- E080Return probe error
- E081Return temperature over limit
- E082Warning delta temperature
- E090Exhaust probe error
- E091Primary heat-exchanger cleaning fault
- E095Calibration failed
- E096Lambda over limit
- E099Reset attempts exhausted