Vokera Vibe fault AF1

Heating anti-freeze protection active

Gas boiler

What it means

Protective status (not a fault lockout) shown when heating anti-freeze function activates because flow sensor temperature drops below 5°C. Burner ignites at minimum output, maintained until delivery water temperature reaches 35°C.

Likely causes

  1. Flow/delivery sensor temperature dropped below 5°C due to low ambient temperature or boiler being off
  2. Flow water temperature below 5°C while boiler in OFF status with electrical and fuel supply active

Where to start

  1. Verify flow sensor temperature reading
  2. Confirm burner ignites at minimum output during this condition

The full answer, free

  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 29), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vokera manual for the Vibe. Check the model on the data plate before you order parts.