Worcester Bosch Greenstar 4000 Combi fault 1013
Max. combustion point reached (the maximum burner time is reached)
Gas boilerWhat it means
Fault category W. Service reminder message present due to the maximum burner hours service threshold being reached.
Likely causes
- Maximum burner hours service threshold reached
- Misfiring ignition transformer
- Incorrect gas type
- Incorrect gas supply pressure
- Power supply issue
- Faulty electrodes or cable
- Damaged or blocked flue system
- Incorrect gas/air ratio
- Faulty external gas flow monitor (natural gas)
- Faulty burner
- Faulty gas valve
- Faulty non-return valve in burner hood assembly
- Faulty seals around the burner
- Faulty internal flue seals
- Faulty case seals
- Flue system integrity problem
- Combustion circuit problem
- Combustion fault
- Cleaners containing chlorine or hydrogen halide (spray cans, primers, cleaners, paint, glue) stored or used near the appliance
- Build-up of dust
Where to start
- Check the ignition transformer function for misfiring in the Function check menu, Ignition test
- Check the gas type
- Check the gas supply pressure
The full answer, free
- 54 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 75), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Worcester Bosch manual for the Greenstar 4000 Combi. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 4000 Combi fault codes
- 1021Cylinder charging or hot water temperature sensor faulty
- 1037Outside temp. sensor faulty - heating backup operation active
- 1065System pressure sensor faulty or not connected
- 1068Outside temp. sensor or lambda probe faulty
- 1073Short-circuit at flow temp. sensor
- 1074No signal from flow temperature sensor
- 1075Heat exchanger temp sensor short circuit
- 1076Heat exchanger temp sensor disconnected
- 2085Internal fault
- 214Fan shut down during safety time
- 224Maximal flue gas thermostat or heat exchanger maximal thermostat has activated (blocking)
- 228Flame signal without flame present
- 234Gas valve electrical fault
- 235Conflicting versions of boiler electr. and boiler identification
- 238Boiler electronics faulty
- 242Boiler electr. system fault
- 245System fault boiler electronics / basic controller
- 249System fault boiler electronics / basic controller
- 250System fault boiler electronics / basic controller
- 251System fault boiler electronics / basic controller
- 252System fault boiler electronics / basic controller
- 253System fault boiler electronics / basic controller
- 254System fault boiler electronics / basic controller
- 258System fault boiler electronics / basic controller