Worcester Bosch Greenstar 4000 Combi fault 224
Maximal flue gas thermostat or heat exchanger maximal thermostat has activated (blocking)
Gas boilerWhat it means
Blocking fault (Category B). Maximal flue gas thermostat or heat exchanger maximal thermostat has activated. If the blocking fault persists for a prolonged period, it becomes a locking fault (also code 224, Category V).
Likely causes
- Lead disconnected from safety temperature limiter/thermostat or flue thermostat
- Safety temperature limiter/thermostat or flue thermostat tripped
- Low system pressure
- Air trapped in the system or boiler
- Pump seized or not running
- Blockage/restriction within boiler/pipework restricting flow
- Faulty seals around the burner
- Faulty internal flue seals
- Faulty case seals
- Flue system integrity problem
- Combustion circuit problem
- Incorrect gas type
- Incorrect gas supply pressure
- Damaged or blocked flue system
- Incorrect gas/air ratio
- Faulty gas valve
- Misfiring ignition transformer
- Power supply issue
- Faulty electrodes or cable
- Faulty external gas flow monitor (natural gas)
- Faulty burner
- Combustion fault
- Damaged or insecure flue joints
- Obstructed or damaged terminal/terminal guard
- Damaged flue pipes or gaskets
- Unauthorised modification of flue gas system
- Leaking flue joints
Where to start
- Check if the lead is disconnected from the safety temperature limiter/thermostat or the flue thermostat.
- Check the high limit of the safety temperature limiter/thermostat or the flue thermostat and the harness for continuity.
- Check the flow temperature to confirm actual temperature (may have tripped out at lower temperature, leading to a safety temperature limiter/thermostat or flue thermostat fault).
The full answer, free
- 60 more checks in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 72), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
From the Worcester Bosch manual for the Greenstar 4000 Combi. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar 4000 Combi fault codes
- 1013Max. combustion point reached (the maximum burner time is reached)
- 1021Cylinder charging or hot water temperature sensor faulty
- 1037Outside temp. sensor faulty - heating backup operation active
- 1065System pressure sensor faulty or not connected
- 1068Outside temp. sensor or lambda probe faulty
- 1073Short-circuit at flow temp. sensor
- 1074No signal from flow temperature sensor
- 1075Heat exchanger temp sensor short circuit
- 1076Heat exchanger temp sensor disconnected
- 2085Internal fault
- 214Fan shut down during safety time
- 228Flame signal without flame present
- 234Gas valve electrical fault
- 235Conflicting versions of boiler electr. and boiler identification
- 238Boiler electronics faulty
- 242Boiler electr. system fault
- 245System fault boiler electronics / basic controller
- 249System fault boiler electronics / basic controller
- 250System fault boiler electronics / basic controller
- 251System fault boiler electronics / basic controller
- 252System fault boiler electronics / basic controller
- 253System fault boiler electronics / basic controller
- 254System fault boiler electronics / basic controller
- 258System fault boiler electronics / basic controller