Worcester Bosch Greenstar 4000 System fault 2085

Internal fault

Gas boiler

What it means

Internal fault (V category) in appliance electronics.

Likely causes

  1. Incoming mains voltage fault
  2. Incorrect polarity
  3. Faulty PCB

Where to start

  1. Check the incoming mains voltage
  2. Check the polarity

The full answer, free

  • How to put it right, step by step
  • The manual page for this fault (page 75), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Worcester Bosch manual for the Greenstar 4000 System. Check the model on the data plate before you order parts.

Other Worcester Bosch Greenstar 4000 System fault codes