Worcester Bosch Greenstar 4000 System fault 227

No flame signal after ignition

Gas boiler
Free account: 9 more checks, the readings and the manual page (page 71). No card needed.See the full 227 answer

What it means

Locking fault (V category): no flame signal was detected after ignition. The boiler locks out until reset.

Likely causes

  1. Damaged ceramic insulator causing the spark to earth.
  2. No or low gas supply to the property or at the gas valve inlet.
  3. Low pressure when the gas valve opens.
  4. Gas valve failing to open because of a voltage problem or a blocked inlet filter.
  5. Obstruction in the air intake to the fan, giving the wrong CO2 ratio.
  6. Condensate siphon blocked or restricted, or condensate pipe frozen.
  7. Flue blocked or restricted.
  8. Heat exchanger blocked or restricted.
  9. Damaged burner.
  10. Failed spark electrode or lead.
  11. Failed flame sense electrode or lead.
  12. Poor rectification ground (black wire to the heat exchanger).

Where to start

  1. Check the ceramic insulator is not damaged: twist and pull to make sure it is not broken.
  2. Check the gas supply to the property and at the gas valve inlet.
  3. Check for a drop in pressure when the gas valve opens.

The full answer, free

  • 9 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 71), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full 227 fix, readings and manual page. Free.See the full answer

From the Worcester Bosch manual for the Greenstar 4000 System. Check the model on the data plate before you order parts.