Worcester Bosch Greenstar i Combi ErP fault EA261
HCM potentially defective
Gas boilerFree account: 1 more check, the readings and the manual page (page 66). No card needed.See the full EA261 answer
What it means
Ignition/ionisation fault: the boiler suspects the HCM (Heating Control Module) is defective.
Likely causes
- HCM not inserted properly.
- Incorrect HCM number.
- Blocked condensate pipes.
Where to start
- Reset the appliance.
- If the error continues, check the HCM is inserted properly.
- Check the HCM number.
The full answer, free
- 1 more check in order
- The readings and component tests from the manual
- How to put it right, step by step
- The manual page for this fault (page 66), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full EA261 fix, readings and manual page. Free.See the full answer
From the Worcester Bosch manual for the Greenstar i Combi ErP. Check the model on the data plate before you order parts.
Other Worcester Bosch Greenstar i Combi ErP fault codes
- 9U233Control box or HCM defective or loose
- C1264Fan stopped during operation
- C4237Control box or HCM defective
- C6215Fan speed too high
- C6216Fan speed too low
- C7214Fan does not run during start-up
- C7217Fan stopped during operation
- E2222Flow temperature sensor shorted
- E2223Flow temperature sensor disconnected
- E2350Flow temperature sensor shorted
- E2351Flow temperature sensor disconnected
- E9276Primary flow temperature exceeded 95°C
- EA227No ionisation after ignition
- EA229Loss of ionisation during operation
- F0238Gas valve or control box error
- F0239Control box or HCM defective
- FA306Ionisation after gas valve closed
- H09Pump communications error
- H29Outdoor sensor defect