Glow-worm Energy System fault F.49

EBUS fault: voltage too low

Gas boiler

What it means

eBUS voltage detected below required level

Likely causes

  1. Short circuit on eBUS
  2. EBUS overload
  3. Two power supplies with different polarities on the eBUS

Where to start

  1. Read d.80 for heating mode running time (value x100 hours)
  2. Read d.81 for DHW mode running time (value x100 hours)
  3. Read d.82 for burner ignitions in heating mode (value x100)

The full answer, free

  • 3 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 51), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.