Glow-worm Energy System fault F.70

Invalid product code (DSN)

Gas boiler

What it means

Device Specific Number is invalid or coding mismatch detected

Likely causes

  1. Display and PCB replaced at same time and Device Specific Number not reset
  2. Wrong or missing output coding resistor
  3. Residual live terminals L and N even when main switch is off
  4. Charged condensers

Where to start

  1. Disconnect the product from the power supply by switching off all power supplies at all poles (electrical partition with a contact gap of at least 3 mm, e.g. fuse or circuit breaker) or remove the mains plug (if present).
  2. Secure against being switched back on again.
  3. Wait at least three minutes until the condensers have discharged.