Glow worm Ultracom 2 fault F68

Flame signal is fluctuating, caused by insufficient gas flow, incorrect gas valve...

Gas boiler
Free account: 1 more check and the manual page (page 37). No card needed.See the full F68 answer

What it means

Flame signal is fluctuating, caused by insufficient gas flow, incorrect gas valve adjustment or defective ignition components.

Likely causes

  1. No return gas / Insufficient gas flow
  2. Gas valve incorrectly adjusted
  3. Defective firing electrode and flame control / Defective igniter unit

Where to start

  1. Check the return gas circuit (gas valve open).
  2. Observe the flame picture and check the CO2 setting.
  3. Check the igniter unit connections.

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 37), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

Full F68 fix, readings and manual page. Free.See the full answer

From the Glow worm manual for the Ultracom 2. Check the model on the data plate before you order parts.

Other Glow worm Ultracom 2 fault codes