Glow worm Ultracom 2 fault S.54

Waiting cycle: lack of water / temperature rise too high

Gas boiler
Free account: 12 more checks, the readings and the manual page (page 33). No card needed.See the full S.54 answer

What it means

Waiting cycle triggered due to lack of water in the installation or temperature rise between heating flow and return being too high.

Likely causes

  1. Lack of water in the installation
  2. Low system pressure
  3. Pump failure
  4. Air lock in system

Where to start

  1. Check system water pressure
  2. Check pump operation
  3. Bleed air from system