Glow worm Ultracom 2 fault F86
Floor heating contact is open or sensor is disconnected/defective
Gas boilerFree account: the manual page (page 37). No card needed.See the full F86 answer
What it means
Floor heating contact is open or sensor is disconnected/defective.
Likely causes
- Floor heating contact open
- Sensor disconnected or defective
Where to start
- Check the sensor connections.
- Check that the sensor is connected to the main board and the shunt is removed.
The full answer, free
- How to put it right, step by step
- The manual page for this fault (page 37), right under the answer
Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.
Full F86 fix, readings and manual page. Free.See the full answer
From the Glow worm manual for the Ultracom 2. Check the model on the data plate before you order parts.
Other Glow worm Ultracom 2 fault codes
- F28Appliance fails to ignite due to insufficient gas flow, incorrect gas valve...
- F29Flame signal is lost while the burner is operating, caused by gas supply or ignition...
- F68Flame signal is fluctuating, caused by insufficient gas flow, incorrect gas valve...
- F76Thermal fuse dry fire protection triggered
- F77Fault in the gas valve motor caused by a defective gas valve or condensate pump
- F84Flow and return heating temperature sensors are inverted, disconnected, or defective
- S.53Waiting cycle: temperature differential between heating flow and return too high
- S.54Waiting cycle: lack of water / temperature rise too high
- S.98Test temperature sensors for heating flow and return, or appliance fault