Grant Aerona R290 fault E24

PFC module temperature is too high

Heat pump

What it means

Power Factor Correction module temperature exceeded limit.

Likely causes

  1. Cables incorrectly connected
  2. Refrigerant & Drive PCB is faulty

Where to start

  1. Check all connections from the Refrigerant PCB (or Refrigerant & Drive PCB for the 16kW model)
  2. Verify correct terminal used for each circuit function per Table 6-6
  3. Confirm no 230V live wiring crosses to the low voltage side of the wiring centre split

The full answer, free

  • 4 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 60), right under the answer

Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

From the Grant manual for the Aerona R290. Check the model on the data plate before you order parts.