Grundfos STP 2 fault 5A

The pump pulses (other taps causing momentary start)

Shower pump

What it means

The use of other taps in the house may cause the pump to start momentarily, resulting in pulsing.

Likely causes

  1. The use of other taps in the house may cause the pump to start momentarily
  2. Water hammer
  3. Low flow rates from cistern filling causing frequent pump cycling
  4. Hot-water supply taken directly from top of hot-water cylinder
  5. Entrapped air causing airlocks in supply pipe
  6. Air not thoroughly purged from system
  7. Leak in system
  8. Drip in system
  9. Air trapped in pump
  10. Non-return valve incorrectly fitted in inlet pipe
  11. Undersized tank causing insufficient supply
  12. Incorrect outlet height causing hot-water-only delivery
  13. Outlet positioned below mains inlet causing air ingress
  14. Non-return valve fitted incorrectly in inlet pipe causing restricted flow or pump damage
  15. Undersized pipework
  16. Pipes routed under floor causing air traps
  17. Other outlets fitted in inlet pipes
  18. Shared (non-dedicated) hot/cold supplies
  19. Blanked-off pipes
  20. Restrictions in flexible hoses
  21. Unsecured pipework
  22. Direct mains connection causing pressure issues or pump damage
  23. Jointing compounds/tape causing blockage or leaks
  24. Shared supply pipe causing air ingress or reduced flow
  25. Missing surrey flange causing air in hot water supply
  26. Blocked strainers common on initial pump installation or new buildings due to jointing compounds, tapes, flux and debris flushed through system
  27. Leak causing loss of tank air pressure
  28. Leaks due to insufficient hose insertion depth
  29. Debris ingress into pump causing blockage or damage if strainer omitted
  30. Leaks due to under-tightened or incorrectly connected hoses
  31. Mechanical strain on pump from misaligned pipework
  32. Solder joint heat damaging plastic pump components
  33. Air pockets from incorrectly routed pipework
  34. Restricted or kinked flexible hoses
  35. Additional outlet fittings on inlet pipework causing incorrect flow switch operation
  36. Mechanical stress on pump from rigid pipe connection
  37. Leaks from use of jointing compound instead of correct hose connections

Where to start

  1. Check taps or other outlets for water hammer
  2. Switch off power supply for ten seconds
  3. Switch power supply back on

The full answer, free

  • 84 more checks in order
  • The readings and component tests from the manual
  • How to put it right, step by step
  • The manual page for this fault (page 14), right under the answer

Safety: Isolate power and water, and prove dead before you open or test the pump.

From the Grundfos manual for the STP 2. Check the model on the data plate before you order parts.