Hitachi Yutaki fault 53
Inverter fin temperature increase
Heat pumpWhat it means
Inverter abnormality due to increase in inverter fin temperature.
Likely causes
- Inverter module (IPM, DIP-IPM) and Inverter PCB abnormality
- Failure of compressor
- Clogging of heat exchanger
Where to start
- Check Water Outlet PHEX Temperature
- Check Water Flow Level and Water Pump Speed
- Check Outdoor Ambient temperature and Outdoor Ambient 2 temperature
The full answer, free
- 11 more checks in order
- The manual page for this fault (page 85), right under the answer
Safety: Isolate the outdoor unit and any backup heater, and give the inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
From the Hitachi manual for the Yutaki. Check the model on the data plate before you order parts.