Joule Ben Dual Air fault 33033
Four-way valve in the wrong position
Heat pumpFree account: the manual page (page 36). No card needed.See the full 33033 answer
What it means
Lockout. BEN shuts down for 30 minutes, then attempts to restart.
Likely causes
- Mechanically wrong valve position
- Defective magnetic coil
- Blockage in the cooling circuit
Where to start
- Check the function of the four-way valve
- Check the control voltage of the four-way valve
The full answer, free
- The manual page for this fault (page 36), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full 33033 fix, readings and manual page. Free.See the full answer
From the Joule manual for the Ben Dual Air. Check the model on the data plate before you order parts.