Joule Ben Dual Air fault 43076
Repeated low evaporating pressure
Heat pumpFree account: 1 more check and the manual page (page 37). No card needed.See the full 43076 answer
What it means
Lockout due to repeated low evaporating pressure.
Likely causes
- Refrigerant loss
- Defective expansion valve
- Faulty sensor
- Ice formation on the evaporator at low outdoor temperatures
Where to start
- Check the evaporator
- Check the expansion valve
- Treat altered sound during defrost (bubbling or running meltwater sounds) as normal
The full answer, free
- 1 more check in order
- How to put it right, step by step
- The manual page for this fault (page 37), right under the answer
Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.
Full 43076 fix, readings and manual page. Free.See the full answer
From the Joule manual for the Ben Dual Air. Check the model on the data plate before you order parts.