Joule Ben Dual Air fault 43076

Repeated low evaporating pressure

Heat pump
Free account: 1 more check and the manual page (page 37). No card needed.See the full 43076 answer

What it means

Lockout due to repeated low evaporating pressure.

Likely causes

  1. Refrigerant loss
  2. Defective expansion valve
  3. Faulty sensor
  4. Ice formation on the evaporator at low outdoor temperatures

Where to start

  1. Check the evaporator
  2. Check the expansion valve
  3. Treat altered sound during defrost (bubbling or running meltwater sounds) as normal

The full answer, free

  • 1 more check in order
  • How to put it right, step by step
  • The manual page for this fault (page 37), right under the answer

Safety: Isolate the heat pump and any backup heater, and give any inverter capacitors time to discharge before you open the electrics. Anything on the refrigerant circuit needs F-gas certification.

Full 43076 fix, readings and manual page. Free.See the full answer

From the Joule manual for the Ben Dual Air. Check the model on the data plate before you order parts.